Features
- Single-channel NO/NC switching
A five-pin changeover relay provides normally open and normally closed contacts for one load circuit.
- 817C optocoupler
The control input uses an 817C optocoupler.
- Status indication and coil protection
An onboard LED indicates output status, and a flyback diode suppresses the voltage spike from the relay coil.
- Screw-clamp terminals
Separate screw terminal blocks secure the control wires and the load wires.
- Compact mounting footprint
The black PCB measures 56.5 × 16.8 × 20 mm overall and has four mounting holes.
Overview
BESTEP 3 V relay module
This black-PCB module pairs a JQC3F-03VDC-C changeover relay with an 817C optocoupler. Separate terminal blocks provide access to the control input and the relay contacts.
Screw terminals and mounting holes
The board has a three-position screw terminal block at each end and a mounting hole at each corner.
Operating Precautions
Disconnect power from both circuits before wiring. The values printed on the relay housing apply to the relay contacts. Verify the complete assembly and the actual load, including inrush current, before use.
Specifications
| Brand | BESTEP |
|---|---|
| Module type | Single-channel optocoupler relay module |
| Nominal relay coil voltage | 3 V DC |
| Relay marking | JQC3F-03VDC-C |
| Contact configuration | SPDT (COM, NO, NC) |
| Relay contact ratings shown on housing | 10 A at 250 V AC / 125 V AC, 10 A at 30 V DC / 28 V DC |
| Optocoupler marking | 817C |
| Control terminals | VCC, IN, GND |
| Response time (stated) | <20 ms |
| Dimensions (L × W × H) | 56.5 × 16.8 × 20 mm |
| Product weight | 15 g |
Package Contents
- 1 × BESTEP 3 V single-channel optocoupler relay module
FAQ
What is the difference between NO and NC?
With the coil de-energized, COM is connected to NC. When the coil energizes, COM switches to NO.
What does the 3 V specification refer to?
It is the nominal relay coil voltage. The load circuit has its own supply and switches through the relay contacts.
Connection & Operating Notes
The control terminal block is labeled VCC, IN, and GND. Check the input trigger level and current requirements before connecting a controller.
No guides have been linked to this product yet.